Mon–Fri: 7am–3pm  |  Walk-In Service
πŸ“ 3428 Stanford Dr NE, Albuquerque NM|Cert. of Approval: MS-14 397477
NFPA 101 Compliant

Emergency Light &
Exit Sign Inspection

When power fails, your emergency lighting must perform. FSI New Mexico provides NFPA 101 compliant inspection and 90-minute discharge testing for commercial buildings, schools, restaurants, and multi-unit properties throughout Albuquerque.

Emergency exit sign with dual emergency lights

Life Safety Lighting β€” A Legal Requirement

Emergency egress lighting exists to guide occupants safely out of a building when smoke, darkness, or chaos make normal navigation impossible. In those critical seconds, a properly functioning emergency light can be the difference between a safe evacuation and a tragedy.

NFPA 101: Life Safety Code mandates emergency lighting in virtually every commercial occupancy. New Mexico's state fire code adopts these requirements, and local fire marshals conduct periodic inspections to verify compliance. Buildings found without properly certified emergency lighting face fines and mandatory remediation orders.

FSI New Mexico's certified technicians perform the complete inspection protocol β€” monthly functional tests, annual 90-minute discharge tests, battery condition assessments, and exit sign verification β€” providing written documentation for every inspection performed. We can easily combine this service with your annual fire extinguisher certification to save your business time and testing fees.

Annual 90-minute testing is required under NFPA 101. We conduct this full-duration discharge test and document results in a signed inspection report.

NFPA 101 Testing Requirements

Our inspection process covers all testing intervals mandated by the Life Safety Code and New Mexico state fire regulations.

1

30-Second Functional Test

NFPA 101 requires a brief functional test every 30 days. The emergency light must illuminate for at least 30 seconds when normal power is interrupted.

2

Annual 90-Minute Discharge Test

Once per year, emergency units must maintain illumination for a full 90 minutes on battery backup power β€” simulating an extended power outage.

3

Exit Sign Visibility Check

All exit signs must be illuminated, visible from 100 feet under normal conditions, and remain lit during power failure from any direction of approach.

4

Battery Condition Assessment

Batteries are inspected for proper voltage, charge retention, and corrosion. Units that fail the 90-minute test require battery replacement or unit replacement.

Equipment We Service

Emergency Lighting Types We Service

We inspect, test, repair, and maintain all types of life safety egress lighting and signage found in commercial buildings.

πŸ’‘

Emergency Light Units

Standard battery-powered dual-head emergency lighting fixtures that illuminate paths of egress.

πŸšͺ

Exit Signs

LED, photoluminescent, and tritium self-luminous exit signs to clearly indicate exit boundaries.

πŸ”„

Combo Units

Space-saving integrated fixtures combining an illuminated exit sign with dual emergency floodlights.

⚑

Inverter Systems

Central backup battery inverter systems that power larger emergency lighting arrays during outages.

Which Buildings Require This Inspection?

Under NFPA 101 and New Mexico fire code, the following occupancy types must maintain compliant emergency egress lighting and signage. If your facility receives members of the public, employs more than a handful of people, or has overnight occupancy β€” you almost certainly need this inspection.

Restaurants & bars Office buildings Retail stores Hotels & motels Schools & daycares Healthcare facilities Warehouses Multi-unit residential Gyms & fitness centers Places of assembly

What's Included in Our Service

  • Complete visual inspection of all emergency units
  • 30-second functional test
  • Full 90-minute battery discharge test (annual)
  • Exit sign illumination and visibility check
  • Battery voltage and condition assessment
  • Written pass/fail report for each unit
  • Documentation ready for fire marshal inspections
  • Recommendations for repair or replacement
Common Questions

Frequently Asked Questions

Find answers to common questions about emergency egress lighting requirements and NFPA 101 compliance.

How often do emergency lights need to be tested?
NFPA 101 (Life Safety Code) mandates two testing intervals: a 30-second functional test every 30 days to confirm basic operation, and a full 90-minute battery discharge test once per year.
What happens during an annual 90-minute discharge test?
During an annual test, our technicians simulate a complete power outage by disconnecting the AC power to the emergency lighting units. The fixtures must remain illuminated on battery power alone for a full 90 minutes while maintaining standard light output levels.
Do you replace batteries or the whole fixture if a light fails?
If a unit fails, we first test the battery. In many cases, we can simply replace the sealed lead-acid or nickel-cadmium battery on-site to restore the fixture to service. If the internal charging circuitry, bulbs, or housing are defective, we recommend replacing the entire unit with a modern, energy-efficient LED fixture.
Are written records of emergency light testing required?
Yes. NFPA 101 requires written logs of all monthly and annual emergency light inspections to be maintained on-site and made available for review by the local fire marshal during routine inspections. FSI New Mexico provides detailed, signed test reports for your compliance binder.

Schedule Your Emergency Light Inspection Today

Don't wait for a failed fire marshal inspection. Walk in anytime Monday–Friday or contact us to schedule on-site service at your Albuquerque-area facility.

Local Compliance Routes

Serving Businesses Throughout Central New Mexico

FSI New Mexico runs daily dispatch routes to commercial, restaurant, and industrial properties in the following cities:

πŸ“ Albuquerque, NM πŸ“ Rio Rancho, NM πŸ“ Santa Fe, NM πŸ“ Los Lunas, NM πŸ“ Corrales, NM πŸ“ Bernalillo, NM πŸ“ Los Ranchos, NM πŸ“ Belen, NM πŸ“ Bosque Farms, NM πŸ“ Peralta, NM πŸ“ Placitas, NM πŸ“ Edgewood, NM πŸ“ Moriarty, NM πŸ“ Tijeras, NM πŸ“ Cedar Crest, NM πŸ“ Sandia Park, NM
Schedule ServiceCall Now
Call Now Request Quote