Mon–Fri: 7am–3pm  |  Walk-In Service
📍 3428 Stanford Dr NE, Albuquerque NM|Cert. of Approval: MS-14 397477
Class A Clean Defense

Water & Water Mist
Fire Extinguishers

Clean, non-toxic, and affordable protection for paper, wood, and organic structural hazards. We provide NFPA 10 inspections, hydrostatic testing, and recharges in Albuquerque.

The Natural Solution for Ordinary Combustibles

Standard pressurized water extinguishers discharge a high-velocity stream of tap water, cooling the burning fuel below its ignition temperature. Specialized de-ionized water mist extinguishers utilize a specialized nozzle that sprays microscopic droplets. Water-based systems are the premier safety standard for:

  • Organic Storage: Paper archives, cardboard warehouses, textile mills, and libraries.
  • Clean Environments: Hospital patient rooms, schools, offices, and garment shops.
  • Food Packaging: Bakeries, wholesale flour warehouses, and packing yards.

Because they are filled with water, they are fully non-toxic, leave no chemical dust or powder, and are extremely cost-effective to recharge. FSI New Mexico helps Albuquerque businesses mount, tag, and pressure-test their water units. De-ionized water mist units are also certified safe for use near energized Class C electrical equipment up to 100,000 volts due to the lack of electrical conductivity in pure, mineral-free water mist.

Warning: Standard water-stream extinguishers must NEVER be used on Class B flammable liquid fires or Class C electrical fires. Doing so will conduct electricity to the operator or spread burning liquid rapidly.

A technician checking fire compliance fixtures

Water & Water Mist Specifications & NFPA 10 Rules

Understanding testing, inspection, and maintenance intervals for pressurized liquid gear.

Specification NFPA 10 / FSI New Mexico Guidelines
Chemical Agent Pressurized Tap Water (Standard) or De-ionized Water (Mist units)
Fires Fought Class A (trash/wood/paper). De-ionized mist units also tested safe for Class C.
Visual Inspection Every 30 days (verify gauge pressure, handle seal, and hose integrity)
Annual Maintenance Physical inspection, weight confirmation, and tagging by a licensed fire service company
Hydrostatic Testing Every 5 years (stainless steel water cylinders must undergo hydrostatic wall testing)

Ensure Your Class A Water Extinguishers Are Certified

We recharge, inspect, and certify water and de-ionized mist cylinders. Drop in Monday-Friday or schedule a service call to your facility.

Schedule ServiceCall Now